Lefdal Mine Datacenter
  • Data Center
    • Facility
    • Power
    • Cooling
    • Connectivity
    • High Security
    • Certifications
  • Why LMD
    • Cost Effective
    • Leading Green
    • Scalability
    • Security
    • Why Norway
  • Services
    • Colocation
    • Containers
    • HPC
    • BUILD TO SUIT
    • SMART HANDS
    • Amenities
  • Sustainability
    • Leading green
    • Limited Transmission Loss
    • Low PUE – 1.10
    • Carbon Neutral
    • No Water Usage
    • Limited Footprint
    • Heat Reuse
    • Green Initiatives
  • News
    • News
    • Press releases
  • Resources
    • 360° tour
    • Videos
    • Brochures
  • About
    • The Norwegian Solution
    • Owners
    • Board Of Directors
    • Management Team
    • Careers
    • Awards and nominations
    • Events
  • Contact
  • Menu Menu

LEADING

DATA CENTER FACILITY

HIGH SECURE

LEVEL 3

80MW

HOUSING SOLUTIONS ARE

OFFERED BOTH IN

CONTAINERS AND DATA HALLS

PURPOUSE BUILT DATA HALLS

PRIVATE SUITS, CAGES OR RACKS

Cooling

European leading Cooling solution

Lefdal Mine Datacenter is one of the world’s most energy effective data centers. The cooling solution will lead to a PUE ranging from 1.08 to 1.15 – depending on UPS configuration and scale of capacity. Less than 3% of the power spent on IT is used for cooling with a 5 KW/rack configuration.

Seawater and freshwater circuit

The solution is based on cold seawater used as cooling source through a heat exchanger for a closed fresh water circuit that cools computers via CRAH, LCP or Zucs solutions.

The proximity to the fjord ensures access to unlimited 8 C seawater year around. The fjord is deep (565 meters) and has four glaciers connected to it.  The mine is situated just below sea level so there is no need to use energy lifting the water.

The seawater will cool down the fresh water circuit from 30 C to 18 C.  The prototype has been running for 10 years in the data centers of LocalHost AS – an IT consultancy and operation company within the group.

Certified by IBM/CH2M Hill

IBM/CH2M HILL concluded that the Lefdal Mine Datacenter cooling solution will enable the facility to run with an industry leading PUE under 1.1 once the design is fully developed. The cooling solution offers 20-30% improvement over current leading edge designs operational or under construction in Europe.

Technical specifications

  • A+B salt water pipelines from the fjord to heat exchangers – 2N redundancy
  • A+B fresh water pipelines from heat exchangers to each designated IT area – 2N redundancy
  • Containment is used to avoid mixing of cold/hot air in the data center

The Data Center

  • Facility
  • Power
  • Cooling
  • Connectivity
  • High Security
  • Certifications

NEWSLETTER

Address

Lefdal Mine Datacenter
Gate 1 nr 101
6700 Måløy

Contact us

post@lefdalmine.com
Phone: +47 56 99 41 91 

Social media

Menu

  • Homepage
  • The Datacenter
  • Why LMD
  • Sustainability
  • News
  • Resources
  • About Lefdal Mine
  • Contact
  • Privacy Policy
Webpage by Frequency.no - SEO texts
  • LinkedIn
  • Twitter
  • Facebook
Scroll to top

This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.

OKLearn more

Cookie and Privacy Settings



How we use cookies

We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.

Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.

Essential Website Cookies

These cookies are strictly necessary to provide you with services available through our website and to use some of its features.

Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.

We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.

We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.

Google Analytics Cookies

These cookies collect information that is used either in aggregate form to help us understand how our website is being used or how effective our marketing campaigns are, or to help us customize our website and application for you in order to enhance your experience.

If you do not want that we track your visit to our site you can disable tracking in your browser here:

Other external services

We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.

Google Webfont Settings:

Google Map Settings:

Google reCaptcha Settings:

Vimeo and Youtube video embeds:

Other cookies

The following cookies are also needed - You can choose if you want to allow them:

Accept settingsHide notification only